A facilities manager in a UAE tower is reviewing the annual energy report. Chilled water, air conditioning, lighting and common-area electricity each have their own line. The lifts, which carry residents, employees and visitors throughout the day, appear nowhere as a separate item.

That omission does not automatically mean the building is wasting energy. Lifts are generally a smaller electricity load than major building services, and their contribution depends on factors such as building height, passenger traffic, operating patterns and equipment condition. The problem is that an unmeasured load cannot be assessed consistently against its own operating history or a recognised performance benchmark.

Building energy reviews naturally gravitate towards cooling and other prominent loads. Dubai’s Demand Side Management Strategy has included programmes for building retrofits, green building requirements and efficient cooling, reflecting the importance of building performance to the emirate’s wider energy objectives.

Vertical transport deserves a place in that conversation, even if its consumption is not the largest figure on the bill.

The central issue is not that every lift represents a major cost. It is that lifts can remain outside the measurement framework used to understand how efficiently a building operates.

Why lifts escape routine energy reviews

A lift is usually managed as a specialist system. Its maintenance, fault reporting, safety checks and service availability may sit with a dedicated contractor, while the building’s energy reporting is handled by facilities management or an energy-services team. These responsibilities serve different purposes, and neither necessarily produces a regular account of electricity consumed by each lift.

Utility bills create another limitation. They generally show the electricity supplied to the property rather than a separate consumption figure for every individual service. Unless submetering or a suitable measurement exercise separates vertical transport from other loads, the facilities team may know the building’s total consumption without knowing what the lifts contribute.

Operating patterns also complicate simple comparisons. A residential tower, a hotel and an office building can have different passenger demand and periods of inactivity. Two lift systems in buildings of similar height may therefore have different energy profiles. A single monthly electricity total cannot explain those differences.

This is why an energy audit should distinguish between a load that is small and a load that has never been properly assessed. The former may reasonably receive less attention; the latter cannot be prioritised intelligently until its consumption and operating context are understood.

Measuring consumption and setting a benchmark

The first step is to establish a consumption baseline. Where practical, electricity should be measured at the lift’s supply, with the measurement period covering representative operating conditions. The assessment should distinguish energy used during travel from energy consumed while the car is idle or on standby. Recording operating hours, traffic patterns, and periods of inactivity helps explain the results rather than treating the total as a performance score on its own.

Published estimates illustrate why local measurement matters. A peer-reviewed analysis of elevator and escalator energy efficiency in Europe reports that lifts typically account for around 3–8% of a building’s electricity consumption, while a 2024 study of vertical transport in high-rise office buildings describes elevator systems as consuming approximately 5–15% of total building energy demand. These estimates use different contexts and should not be treated as a single universal range. Neither establishes the share attributable to lifts in UAE buildings.

A recognised method can make the assessment more consistent. ISO 25745 is a series of international standards covering the energy performance of lifts, escalators and moving walks. Part 1 specifies methods for measuring actual energy consumption and conducting periodic verification checks on equipment in operation. Part 2 sets out methods for estimating annual lift energy consumption using measurements, calculations or simulation, and provides a classification system for applicable lift types.

Under Part 2, the lift’s energy classification runs from A to G, with A representing the more efficient performance category and G the less efficient one. The assessment considers both running performance and energy consumed while idle or on standby, rather than judging efficiency solely by the power needed to move a car. Classification also depends on the standard’s calculation method and relevant operating assumptions, so the letter should be interpreted alongside the underlying assessment.

For owners comparing existing equipment, a documented baseline and a consistent classification method provide a more useful starting point than a general claim that a lift is efficient. A practical reference to how lift performance can be assessed and maintained over time can sit alongside the formal measurement methodology, but it does not replace a measured assessment against the standard.

There is a UAE policy context for this work. Dubai’s Demand Side Management Strategy sets wider energy-efficiency objectives and includes building-related programmes, while Abu Dhabi’s Estidama Pearl Rating System evaluates sustainability across areas including energy and water. These frameworks establish a broader case for assessing building performance. However, their general objectives should not be interpreted as proof that every building energy review separately measures lifts or that vertical transport is explicitly required as an individual energy-audit category. That distinction needs to be checked against the applicable requirements and the scope of each assessment.

Operational measures worth checking first

Before proposing a major upgrade, facilities teams can review how existing equipment behaves between journeys. Standby or sleep modes reduce the power used by eligible lift components when a car is inactive. Depending on the system, this can involve switching off or reducing the power to selected lighting, displays, or other non-essential functions. The relevant settings must preserve required safety functions and service availability.

Cabin lighting is another straightforward inspection point. Replacing inefficient lighting with LEDs can reduce the electricity needed to illuminate the car, while appropriate controls can prevent lights from remaining fully on when the lift is unused. The actual benefit depends on the existing lighting, its operating hours, and how the controls are configured.

Regenerative drives offer a different approach. Under suitable operating conditions, they recover some of the energy generated by the lift’s motor during movement and feed it back into the building’s electrical system instead of dissipating it as heat. The amount recovered depends on factors such as the lift’s design, loading and travel patterns; the presence of regenerative equipment alone does not establish a particular saving.

Preventive maintenance also matters, although its energy impact should not be overstated. Correctly adjusted equipment, sound mechanical components and functioning controls help keep a lift operating as intended. Maintenance records can reveal recurring faults or control problems that merit investigation, but a service visit should not automatically be counted as an energy-efficiency improvement.

These checks fit within a wider review of practical measures for improving lift operation and efficiency. The appropriate priority is to identify the condition and operating behaviour of the installed equipment before assuming that a particular intervention will deliver a meaningful reduction.

Giving vertical transport a place in the audit

For a building owner or facilities manager, a better audit scope starts with a simple requirement: account for lifts explicitly, even when their consumption is expected to be modest. The assessment should identify the lift inventory, available electrical metering, equipment age, maintenance history, and typical traffic patterns. Where direct measurement is impractical, any estimate should state its assumptions and limitations.

The report should then establish a baseline, distinguish running from idle consumption where the methodology permits, and record a suitable performance classification if one has been calculated. Operational checks should follow, with proposed changes prioritised according to the evidence, expected operational benefit and cost of implementation. Any later comparison should use consistent measurement conditions so that changes in passenger demand are not mistaken for improvements in equipment efficiency.

Responsibilities also need to be clear. The facilities team should own the energy reporting requirement, while the lift maintenance contractor supplies the technical information and supports access to relevant measurements. Without that handover, the lift can remain outside the building’s energy review even when both parties are meeting their separate contractual obligations.

A building cannot manage an energy load it has never made visible, and a lift does not become efficient simply because its electricity consumption has never been questioned.